What spray foam insulation actually is

Spray polyurethane foam arrives as two liquids. They are kept separate, heated, and combined at the gun, where they react and expand within seconds against whatever surface they were sprayed onto. That reaction is the whole point: the foam expands into gaps, cracks and irregular cavities that a batt has to be cut around and usually is not.

The result is one material doing two jobs. It resists heat flow, like any insulation. It also forms an air barrier, which most insulation does not.

Why the air barrier matters more than people expect

Insulation is sold on R-value, and R-value is a real thing — but it describes resistance to heat moving through a material, measured under still-air laboratory conditions. It does not describe what happens when cold air moves straight past that material through a gap.

In a lot of Canadian buildings, particularly older ones, a meaningful share of the heat loss is air simply leaking out, dragging warmth with it. You can add depth to an attic indefinitely and not fix that. Sealing the path is what changes the bill.

This is also why a badly installed foam job disappoints. If the crew misses the penetrations, the top plates and the rim joist, you have paid a premium for a material whose main advantage was never used.

The standard that governs it

In Canada, the material standard for spray-applied polyurethane foam is CAN/ULC-S705. It covers the foam itself and the way it is applied. There is also a national installer certification programme run by the Canadian Urethane Foam Contractors Association.

Neither of these is a marketing badge. They exist because SPF is a chemical product that cures on site, in your building, under conditions the manufacturer cannot control. The installer is part of the product in a way that is not true of a batt you unwrap.

When we introduce you to an installer, checking this is part of what we check.

Where foam belongs

Foam earns its cost where the alternative cannot do the job:

  • Rim joists and band joists — awkward, leaky, and nearly impossible to seal properly with anything else.
  • Cathedral and low-clearance roofs — where there is no room for the depth of conventional insulation.
  • Crawlspaces and basements — where moisture and air movement both need addressing at once.
  • Metal buildings, shops and agricultural structures — where condensation on the underside of steel is the actual problem, not heat loss.
  • Irregular framing — anywhere the cavity is not a clean rectangle.

Where it does not

An open, accessible attic floor with plenty of headroom is usually a poor argument for foam. Blown cellulose or fibreglass will get you the same thermal result for less money, and the honest answer is to seal the penetrations and then bury them in something cheap.

Anyone who tells you every surface of your building should be foamed is selling, not assessing.

The part that needs a professional eye

Where foam goes wrong, it is nearly always about vapour and moisture rather than temperature — and the correct answer genuinely differs across the country. A wall assembly on the BC coast, built to shed rain, does not want the same treatment as a dry-cold Prairie wall, and neither behaves like a humid Ontario basement with air conditioning running all summer.

That is a building-science question about your specific assembly. It is exactly the sort of thing to ask an installer before the trailer arrives, and a good one will answer it without being prompted.